Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System

Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System
Author :
Publisher :
Total Pages : 144
Release :
ISBN-10 : OCLC:1008966524
ISBN-13 :
Rating : 4/5 (24 Downloads)

Book Synopsis Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System by : Bryan Remley

Download or read book Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System written by Bryan Remley and published by . This book was released on 2017 with total page 144 pages. Available in PDF, EPUB and Kindle. Book excerpt: There is a need to better understand the risks of low level radiation dose in medical diagnostic procedures and ensure that dose measurements are accurate and traceable to National Standards. Users of instruments typically calibrate their dosimeters with one type of radiation beam with a specific photon energy spectrum (referred to as beam quality) and then may use these dosimeters to measure radiation in other types of radiation beam qualities over a different range of photon energies. This is not a problem if the dosimeter response is relatively constant for a broad range of photon energies. However, the response of the optically stimulated luminescent (OSL) dosimeters studied in this work have a relatively strong energy dependence for photons with energies less than 100 keV. Moreover, since this work focused on measuring doses in diagnostic units only, where the mean photon energies are below 100 keV, using a single calibration based on an 80 kVp beam quality as provided by the vendor of the system could result in inaccurate dose measurements. To address this hypothesis, as part of this work, the system was calibrated independently using other beam qualities that better match those of diagnostic units including: RQR50, RQR60, M60, M80 and M100 (Lamperti & O'Brien, 2001), available at the National Institute of Standards and Technology (NIST). A comparison was then made of the air kerma measured by the OSL system using both the vendor's OSL reader calibration and the independent calibration implemented in this work. This comparison shows that when measuring air kerma in x-ray beams with beam qualities that have energy spectra different than the energy spectra of the x-ray beam in which the vendor prepared their calibration set (80 kVp x-ray beam), significant differences of up to 20% are observed. Because of this comparison, a set of beam quality correction factors (BQCF) were developed that allows correcting the air kerma values measured with the vendor's calibrated OSL system, to account for the differences in energy spectra in the air kerma measurement for different beam qualities and ensuring traceability to the national standard for air kerma.


Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System Related Books

Characterization of a Commercial Optically Stimulated Luminescence Dosimetry System
Language: en
Pages: 144
Authors: Bryan Remley
Categories: Diagnostic imaging
Type: BOOK - Published: 2017 - Publisher:

DOWNLOAD EBOOK

There is a need to better understand the risks of low level radiation dose in medical diagnostic procedures and ensure that dose measurements are accurate and t
Optically Stimulated Luminescence Dosimetry
Language: en
Pages: 375
Authors: L. Boetter-Jensen
Categories: Science
Type: BOOK - Published: 2003-10-24 - Publisher: Elsevier

DOWNLOAD EBOOK

Optically Stimulated Luminescence (OSL) has become the technique of choice for many areas of radiation dosimetry. The technique is finding widespread applicatio
Development and Characterization of Remote Radiation Dosimetry Systems Using Optically Stimulated Luminescence of Al2O3:C and KBr:Eu
Language: en
Pages:
Commissioning of an Optically Stimulated Luminescence Dosimetry (OSLD) System for in Vivo Dosimetry
Language: en
Pages:
Authors: Offormata Emmanuel Osunkwor
Categories:
Type: BOOK - Published: 2018 - Publisher:

DOWNLOAD EBOOK

"A commercial OSL dosimetry system was investigated for passive in vivo dosimetry in radiationtherapy. Al2O3:C OSLDs have been characterized by various authors