Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System

Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System
Author :
Publisher :
Total Pages : 56
Release :
ISBN-10 : OCLC:227840417
ISBN-13 :
Rating : 4/5 (17 Downloads)

Book Synopsis Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System by :

Download or read book Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System written by and published by . This book was released on 1954 with total page 56 pages. Available in PDF, EPUB and Kindle. Book excerpt: A three-column ion exchange test program on Vitro leach liquors was run to compare the performance of IRA-400 and XE-75 resins with respect to loading, elution, and poisoning characteristics. When a high molybdenum liquor was used as feed to the columns, molybdenum poisoning was shown to occur with both IRA-400 and XE-75 resins; however, this poisoning action was much less rapid and less extensive in the case of XE-75. In this respect the XE-75 was found to be similar to Permutit SE. The use of a six percent caustic regenerant completely restored the ion exchange properties of the poisoned XE-75 resin. A cyclic resin-in-pulp process for recovery of uranium from Vitro leach liquors and pulps was studied. The Winchester cell was employed for this investigation in conjunction with XE-123 resin - - a plust 20 mesh resin with the exchange characteristics of XE-75. Performance data, including the effects of molybdenum poisoning, indicate that a 12 cell string may be used effectively with seven cells on exhaustion and five on elution.


Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System Related Books

Recovery of Uranium from Vitro Leach Liquors by Ion Exchange. Part II. Cyclic Column Tests Comparing IRA-400 and XE-75 Resins and Cyclic Testing of a Resin-in-Pulp System
Language: en
Pages: 56
Authors:
Categories:
Type: BOOK - Published: 1954 - Publisher:

DOWNLOAD EBOOK

A three-column ion exchange test program on Vitro leach liquors was run to compare the performance of IRA-400 and XE-75 resins with respect to loading, elution,
Recovery of Uranium from Vitro Leach Liquors by Ion Exchange
Language: en
Pages: 58
Authors: Norman N. Schiff
Categories: Ion exchange
Type: BOOK - Published: 1954 - Publisher:

DOWNLOAD EBOOK

Nuclear Science Abstracts
Language: en
Pages: 898
Authors:
Categories: Nuclear energy
Type: BOOK - Published: 1956 - Publisher:

DOWNLOAD EBOOK

ACCO
Language: en
Pages: 58
Authors:
Categories:
Type: BOOK - Published: 1954 - Publisher:

DOWNLOAD EBOOK

TID.
Language: en
Pages: 252
Authors:
Categories: Energy development
Type: BOOK - Published: 19?? - Publisher:

DOWNLOAD EBOOK